Turner Explosion Protection Systems supply mechanical handling
equipment (MHE) conversions for surface, mining and military
applications, which comply to the essential health and safety
requirements of the ATEX directive 94/9/EC and/or with the
following standards:
• BS EN 1755:2000 Safety of industrial trucks - Operation
in potentially explosive atmospheres - Use in flammable gas,
vapour, mist and dust. for Forklifts.
• BS EN1834-1:2000 Reciprocating internal combustion engines -
Safety requirements for design and construction of engines for use
in potentially explosives atmospheres - Part1: Group II engines for
use in flammable gas and vapour atmospheres.
• BS EN1834-2:2000 Reciprocating internal combustion engines -
Safety requirements for design and construction of engines for use
in potentially explosive atmospheres. Group I engines for use in
underground workings susceptible to firedamp and/or combustible
dust.
• BS EN1834-3:2000 Reciprocating internal combustion engines -
Safety requirements for design and construction of engines for use
in potentially explosive atmospheres. Group II engines for use in
flammable dust atmospheres.
• MoD - JSP 482 July 2008, Chapter 16, Edition 3. Vehicles and
mobile mechanical handling equipment (MHE) in explosives
facilities.
When specifying a new piece of (civilian) MHE, the following
questions need to be addressed:
• Equipment Group - I (mining) or II (surface).
• Area Classification - Zone 1 (gas), Zone 2 (gas), Zone 21
(dust), Zone 22 (dust) or Safe Area.
Refer to BS EN60079-10-1 (gas) and Refer to BS EN60079-10-2
(dust).
• Equipment Category - M2, 2G, 3G, 2D or 3D (derived from area
classification).
• Gas Grouping (for gas atmospheres) - IIA, IIB or IIC.
Refer to EN 60079-20:2000.
• Dust Grouping (for dust atmospheres) - IIIA, IIIB or
IIIC
Refer to EN61241 series.
• Temperature Class - T3 (200°C), T4 (135°C), etc.
Refer to EN 60079-20:2000 (gas) and EN61241 series (dust).
For military MHE, the following questions need to be
addressed:
• Category of Potentially Explosive Site (PES) - Category A
(gas), Category B (dust) or Category C (explosives).
• Area Classification - Zone 1 (gas), Zone 2 (gas), Zone 21
(dust) or Zone 22 (dust).
• Equipment Category - 2G, 3G, 2D or 3D.
• Gas Grouping (for gas atmospheres) - IIA, IIB or IIC.
• Dust Grouping (for dust atmospheres) - IIIA, IIIB or
IIIC.
For Equipment Category 3G working in Zone 2 formally classified
hazardous areas, Turner Explosion Protection Systems fit the 3G
AIR® infra-red gas detection system. Follow link here…
For Added Safety when working in Safe Areas and handling
flammable gas, Turner Explosion Protection Systems fit the AIR
Safe® infra-red gas detection system. Follow link here…